HS-Flow Control Chamber DN/OD 800

HS-Flow Control Chamber DN/OD 800

Controlled discharge of rainwater

The use of a HS®- Flow Control Chamber DN/OD 800 is worth considering wherever rainwater should be directed into the public sewer system. This is the case, for example, after running-off a
rainwater treatment system or an attenuation tank. The dosing element inside the chamber can be supplied adjusted to customer requirements.

The following maximum runoff rates are possible:

Number of D-Raintank®-Layers

(Height of the tank)

Height overflow up to

bore hole (HÜ) mm

Maximum

runoff rate l/s

 

 

 

1 Layer (0.4 m)

250

14

2 Layers (0.8 m)

650

22

3 Layers (1.2 m)

1050

29

 

In order to avoid a total failure of the system in the case of blockages of the dosing element, there is an overflow DN/OD 160 situated directly behind the dosing element. Below the inlet and the dosing element there is a sedimentation zone that can be cleaned with the help of suction vehicle.

 

The advantages in practice:

  • controlled dischargeof rainwater
  • dosing element can be adjusted if required